New builds
Loads, distribution, routes and connections are coordinated with architecture, structure and other engineering systems.
SIA KULMEN develops technical solutions for power supply and electrical installations, prepares related documentation and performs electrical measurements. These services define the intended solution before installation, then help verify important parameters and record the system that was actually built when the work is completed.
Design may be required for a new building, refurbishment, connection of production equipment, modernisation of a distribution system or an installation extension. The content is adapted to the project stage, technical brief and information needed for construction, coordination or subsequent operation and maintenance.
Documentation may include layouts, diagrams, load and material information, cable or equipment references and completion data. The measurement types are selected for the particular installation and purpose, such as checks following new work, assessment after modifications or investigation of the condition of an existing system.
KULMEN can combine design, installation support, recording of changes and final checks within one coordinated process. Where only partial initial information is available, the property is first surveyed, existing elements are identified and unresolved questions are clarified before a complete technical solution is prepared.
The technical solution considers supply parameters, expected loads, room functions, equipment locations, control needs and interaction with other engineering systems. The required level of detail depends on the construction stage and the people who will use the documents during installation, coordination and later maintenance.
For an existing building, design often begins by comparing available diagrams with actual site conditions. A survey identifies sections that can remain, distribution possibilities and missing information, reducing the need to make technical decisions during installation without adequate evidence or coordination.
Clear documentation helps the installer understand the intended solution, the customer review the scope and the facility manager identify circuits and equipment later. The document set is agreed for the task because a limited alteration and a complex property development require different levels of technical detail.
If routes, equipment or connections change during installation, relevant changes should be reflected in the final materials. Completion information may include revised diagrams, labelling, equipment lists and other agreed data that support future maintenance, fault finding or extension of the electrical system.
Depending on the installation, measurements may cover insulation resistance, continuity of protective conductors, earthing, loop parameters and the operation of protective devices. The exact set of checks follows the system type, condition and purpose of the assessment rather than one unchanged checklist for every property.
Work begins by clarifying the brief, diagrams and site access. Following the survey, a solution or measurement plan is prepared, the required work is completed and the findings are compiled. The customer receives the agreed records in a clear form with the inspected parts and results identified.
Electrical design defines the intended solution before installation, while as-built documentation records how it was actually implemented.
Scope depends on the property, construction process, network parameters and stakeholder requirements. Site changes must be reflected so final records correspond to the installed system.
Loads, distribution, routes and connections are coordinated with architecture, structure and other engineering systems.
Existing boundaries, available capacity and the reliability of current records are checked first.
Current diagrams, approved changes, test results and agreed handover documents are compiled.
Electrical testing provides verifiable data for defined installation parameters; the required test set depends on the system and purpose.
Protective-conductor continuity, insulation, earthing, protective devices and other tests may be required. Results are evaluated with the visual inspection, diagrams and protection arrangements.
The agreed scope is verified before handover and recorded in clear documentation.
Testing can assess parameters, support fault finding or prepare for refurbishment.
Method, boundaries and evaluation are selected for the particular system and applicable requirements.
Practical answers
Explore the services and product categories that can form a complete solution for one property.
Send the property address, a short description and any available drawings or documentation. We will review the initial information and clarify the next step.
We'll get back to you shortly
We'll get back to you shortly.